Simple and sensitive LC-ESI-MS method for estimation of sildenafil in plasma samples

Author Affiliations

  • 1Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India
  • 2Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India
  • 3Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India

Res.J.chem.sci., Volume 15, Issue (1), Pages 1-7, February,18 (2025)

Abstract

The quantity of sildenafil in human plasma was determined using a simple and incredibly accurate LC-ESI-MS approach. Thermo, Hypurity Cl8, 100*4.6 mm, 5µm, was injected with sildenafil and sildenafil d3 (internal standard), which were extracted from the plasma using the solid phase extraction technique. Acetonitrile: 0.1% Formic Acid (70:30, v/v) made up the mobile phase, which was supplied isocratically at a flow rate of 0.6 mL/min. The run time was 3 minutes, and the MRM mode for sildenafil and internal standard sildenafil d3 was found at m/z 475.2→283.2 and 478.2→283.2. The calibration curve for sildenafil was linear between 25.0 and 2000 ng/mL, and the detection limit was 25.0 ng/mL. A validated LC-MS/MS method was used to determine drug concentrations.

References

  1. Vardi, M., & Nini, A. (2007)., Phosphodiesterase inhibitors for erectile dysfunction in patients with diabetes mellitus., Cochrane Database of Systematic Reviews, (1).
  2. Ralph, D., & McNicholas, T. (2000)., UK management guidelines for erectile dysfunction., BMJ, 321(7259), 499-503.
  3. Cohen, J. S. (2000)., Sildenafil and nonnitrate antihypertensive medications., JAMA, 283(2), 201-202.
  4. Pistos, C., Papoutsis, I., Dona, A., Stefanidou, M., Athanaselis, S., Maravelias, C., & Spiliopoulou, C. (2008)., Off-line HPLC method combined to LC–MS for the determination of sildenafil and its active metabolite in post-mortem human blood according to confirmation criteria., Forensic Science International, 178(2-3), 192-198.
  5. Lewis, R. J., Johnson, R. D., & Blank, C. L. (2006)., Quantitative determination of sildenafil (Viagra®) and its metabolite (UK-103,320) in fluid and tissue specimens obtained from six aviation fatalities., Journal of analytical toxicology, 30(1), 14-20.
  6. Dumestre-Toulet, V., Cirimele, V., Gromb, S., Belooussoff, T., Lavault, D., Ludes, B., & Kintz, P. (2002)., Last performance with VIAGRA®: post-mortem identification of sildenafil and its metabolites in biological specimens including hair sample., Forensic science international, 126(1), 71-76.
  7. Tsokos, M., & Fehlauer, F. (2001)., Post-mortem markers of sepsis: an immunohistochemical study using VLA-4 (CD49d/CD29) and ICAM-1 (CD54) for the detection of sepsis-induced lung injury., International journal of legal medicine, 114, 291-294.
  8. Ku, H. Y., Shon, J. H., Liu, K. H., Shin, J. G., & Bae, S. K. (2009)., Liquid chromatography/tandem mass spectrometry method for the simultaneous determination of vardenafil and its major metabolite, N-desethylvardenafil, in human plasma: application to a pharmacokinetic study., Journal of Chromatography B, 877(1-2), 95-100.
  9. Nevado, J. B., Flores, J. R., Penalvo, G. C., & Farinas, N. R. (2002)., Determination of sildenafil citrate and its main metabolite by sample stacking with polarity switching using micellar electrokinetic chromatography., Journal of Chromatography A, 953(1-2), 279-286.
  10. Weinmann, W., Bohnert, M., Wiedemann, A., Renz, M., Lehmann, N., & Pollak, S. (2001)., Post-mortem detection and identification of sildenafil (Viagra) and its metabolites by LC/MS and LC/MS/MS., International Journal of Legal Medicine, 114, 252-258.
  11. Wang, Y., Wang, J., Cui, Y., Fawcett, J. P., & Gu, J. (2005)., Liquid chromatographic-tandem mass spectrometric method for the quantitation of sildenafil in human plasma., Journal of Chromatography B, 828(1-2), 118-121.
  12. Vos, R. M., Chahbouni, A., Sinjewel, A. & Swart, E. L. (2008)., Quantitative analysis of sildenafil and desmethylsildenafil in human serum by liquid chromatography–mass spectrometry with minimal sample pretreatment., Journal of Chromatography B, 876(2), 283-287.
  13. Langtry, H. D. & Markham, A. (1999)., Sildenafil: a review of its use in erectile dysfunction., Drugs, 57(6), 967-989.
  14. Meesters, R., & Voswinkel, S. (2018)., Bioanalytical method development and validation: from the USFDA 2001 to the USFDA 2018 guidance for industry., J. Appl. Bioanal, 4(3), 67-73.
  15. Submissions—Content, A. N. D. A. (2014)., Guidance for Industry., Center for Biologics Evaluation and Research (CBER).