
	<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.0//EN" "http://www.ncbi.nlm.nih.gov:80/entrez/query/static/PubMed.dtd">
	<ArticleSet>

	<Article> 

	<Journal> 

	<PublisherName>International Science Community Association</PublisherName>

	<JournalTitle>Research Journal of Chemical Sciences</JournalTitle> 

	<Issn>2231 - 606X</Issn>

	<Volume>1</Volume>

	<Issue>3</Issue>

	<PubDate PubStatus="ppublish"> 

	<Year>2011</Year> 

	<Month>June</Month> 

	<Day>18</Day> 

	</PubDate>

	</Journal>



	<ArticleTitle>Reductimetric Determination of Copper (II) with Iron (II) in Phosphoric Acid Medium and in Presence of Bromide ion</ArticleTitle> 


	<FirstPage>6</FirstPage>

	<LastPage>9</LastPage>



	<ELocationID EIdType="pii"></ELocationID>

	<Language>EN</Language> 
	<AuthorList>

	
		<Author> 

		<FirstName>PatruduT.B.</FirstName>

		<MiddleName> </MiddleName>

		<LastName>K.V.</LastName>

		<Suffix>1</Suffix>

		<Affiliation> Depertment of Chemistry, GITAM University, Hyderabad campus, College of Engineering, Visakhapatnam, INDIA </Affiliation>

		</Author>
		<Author> 

		<FirstName>K.V</FirstName>

		<MiddleName> </MiddleName>

		<LastName>Raju</LastName>

		<Suffix>2</Suffix>

		<Affiliation> Department of Engineering Chemistry, Andhra University, College of Engineering, Visakhapatnam, INDIA </Affiliation>

		</Author>

	<Author>

	<CollectiveName></CollectiveName>>

	</Author>

	</AuthorList>


	<PublicationType>Research Paper</PublicationType>


	<History>  
	<PubDate PubStatus="received">
	<Year>2011</Year>
	<Month>4</Month>
	<Day>14</Day>
	</PubDate>
	<PubDate PubStatus="accepted">										
	<Year>2011</Year> 
	<Month>June</Month>									
	<Day>18</Day> 
	</PubDate>

	</History>
	<Abstract>A simple, accurate and convenient reductimetric titration method has been developed for the determination of copper(II) with iron(II). The method consists in titrating copper(II) against iron(II) in a medium containing 7.8M phosphoric acid and about 1.8M potassium bromide, either potentiometrically or visually using a thiazine dye, an oxazine dye or cacotheline as a redox indicator. Copper (II) in the range of 10-30 mg has been determined by the two methods. The accuracy of the potentiometric method is found to be + 0.5% while that of the visual indicator method is + 0.6%. The precision of the methods has been assessed by computing the pooled standard deviations and 95% confidence limits. The conditional redox potentials of the oxidant and reductant systems have been measured. Based on these potentials data the feasibility of the redox reaction has been explained. The interferences due to diverse ions have been studied. </Abstract>

	<CopyrightInformation>Copyright@ International Science Community Association</CopyrightInformation>

	<ObjectList> 
	<Object Type="keyword">
	<Param Name="value"></Param>
	</Object>

	</ObjectList>	

	</Article>

	</ArticleSet>
	