	<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.0//EN" "http://www.ncbi.nlm.nih.gov:80/entrez/query/static/PubMed.dtd">
	<ArticleSet>

	<Article> 

	<Journal> 

	<PublisherName>International Science Community Association</PublisherName>

	<JournalTitle>Research Journal of Material Sciences</JournalTitle> 

	<Issn>2320 - 6055</Issn>

	<Volume>4</Volume>

	<Issue>4</Issue>

	<PubDate PubStatus="ppublish"> 

	<Year>2016</Year> 

	<Month>May</Month> 

	<Day>16</Day> 

	</PubDate>

	</Journal>



	<ArticleTitle>Measurement of Energy Resolution and Detection Efficiency of NaI(Tl) Scintillation Gamma Ray Spectrometer for Different Gamma Ray Energies</ArticleTitle> 


	<FirstPage>7</FirstPage>

	<LastPage>12</LastPage>



	<ELocationID EIdType="pii"></ELocationID>

	<Language>EN</Language> 
	<AuthorList>

	
		<Author> 

		<FirstName>Sakharam D Aghav</FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>1</Suffix>

		<Affiliation>Physics Department, Baburaoji Gholap College, Sangvi, Pune (SPPU), MS, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Jyoti Kamble</FirstName>

		<MiddleName> </MiddleName>

		<LastName></LastName>

		<Suffix>2</Suffix>

		<Affiliation>Physics Department, Baburaoji Gholap College, Sangvi, Pune (SPPU), MS, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Pooja Baba</FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>3</Suffix>

		<Affiliation>Physics Department, Baburaoji Gholap College, Sangvi, Pune (SPPU), MS, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>J. Y. Yande </FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>4</Suffix>

		<Affiliation>Physics Department, Baburaoji Gholap College, Sangvi, Pune (SPPU), MS, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Gajanan L. Bhor</FirstName>

		<MiddleName> </MiddleName>

		<LastName>  </LastName>

		<Suffix>1</Suffix>

		<Affiliation>Department of Botany, Hutatma Rajguru Mahavidyalaya , Rajgurunagar, Pune, MS, 410505 India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Shubhangi Kharate</FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>2</Suffix>

		<Affiliation>Department of Physics, Hutatma Rajguru Mahavidyalaya , Rajgurunagar, Pune, MS, 410505 India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Sujata Nikam</FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>3</Suffix>

		<Affiliation>Department of Physics, Hutatma Rajguru Mahavidyalaya , Rajgurunagar, Pune, MS, 410505 India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Vasudeo D. Kulkarni </FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>4</Suffix>

		<Affiliation>Department of Physics, Hutatma Rajguru Mahavidyalaya , Rajgurunagar, Pune, MS, 410505 India</Affiliation>

		</Author>
		<Author> 

		<FirstName>G.R. Pansare</FirstName>

		<MiddleName> </MiddleName>

		<LastName>  </LastName>

		<Suffix>1</Suffix>

		<Affiliation>Department of Physics, Haribhai V. Desai Collage, Pune-411002, Maharashtra, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>S.J. Ansari</FirstName>

		<MiddleName> </MiddleName>

		<LastName>  </LastName>

		<Suffix>2</Suffix>

		<Affiliation>Department of Physics, Haribhai V. Desai Collage, Pune-411002, Maharashtra, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>U.R. Kamthe </FirstName>

		<MiddleName> </MiddleName>

		<LastName> </LastName>

		<Suffix>3</Suffix>

		<Affiliation>Department of Physics, Haribhai V. Desai Collage, Pune-411002, Maharashtra, India</Affiliation>

		</Author>

	<Author>

	<CollectiveName></CollectiveName>>

	</Author>

	</AuthorList>


	<PublicationType>Research Paper</PublicationType>


	<History>  
	<PubDate PubStatus="received">
	<Year>2016</Year>
	<Month>2</Month>
	<Day>15</Day>
	</PubDate>
	<PubDate PubStatus="accepted">										
	<Year>2016</Year> 
	<Month>May</Month>									
	<Day>16</Day> 
	</PubDate>

	</History>
	<Abstract>NaI (Tl) scintillation detector is widely used in experimental Physics for the measurement of induced gamma ray activity of various samples. This detector is used in the measurement of nuclear reaction Cross-section induced by neutrons and protons in activation Technique. In addition, Scintillation detector has lot of applications in the elemental analysis of various compounds, alloys using activation analysis. In each application, the precise values of detection efficiency for different gamma energies are essential. To avoid the interference of different gamma energies, knowledge of detector resolution for different gamma energies is necessary.  The values of detection efficiency and resolution vary with detector size and different detector parameters. Therefore it is essential to know these values for given detector before application of detector for the quantitative analysis purpose. With this intention, in the present work, the detection efficiency and resolution of NaI(Tl) scintillation detector are measured and optimized for following gamma ray energies: 122KeV, 356KeV, 511KeV, 662KeV, 1170KeV and 1330KeV. Values of detection efficiencies for these gamma energies are found to be respectively 60.49%, 30.36%, 12.50%, 10.84%, 6.82%, and 5.89%. The values of percentage resolution for above different gamma ray energies are found to be 9.26%, 8.25%, 7.38%, 7.18, 6.32% and 5.32% respectively. The standard gamma ray sources provided by BARC are used in the present research work. The result shows that the efficiency of NaI (Tl) detector decreases with increasing gamma energy</Abstract>

	<CopyrightInformation>Copyright@ International Science Community Association</CopyrightInformation>

	<ObjectList> 
	<Object Type="keyword">
	<Param Name="value"></Param>
	</Object>

	</ObjectList>	

	</Article>